Support Industrielle sensorer
Support Explosion Protection

Ikke tilgængelig for indkøb

This product has been replaced.Go to replacement product HiC2441
Ikke tilgængelig for indkøb
Ikke tilgængelig for indkøb

SMART Universal Barrier HiC2441

HiC2441
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Analog input, digital input,
    analog output, digital output
  • No configuration required, device is self-adapting
  • HART transparency
  • Low power dissipation
  • 3-way isolation
  • Up to SIL 2 acc. to IEC 61508 in preparation

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   HiC2441

General specifications
Signal typeUniversal
Supply
ConnectionSL1: 1a(-), 1b(-); 2a(+), 2b(+)
Rated voltage19 ... 30 V DC via Termination Board
Ripple≤ 10 %
Rated current≤ 30 mA
Power consumption≤ 700 mW
Analog input
Suitable field devices2-wire SMART transmitters, current sources
Signal0/4 ... 20 mA , limited to approx. 40 mA (depends on control system) , reverse polarity protected
Field circuitSL2: 5a(+), 5b(-) (2-wire SMART transmitter)
SL2: 5a(+), 1b(-) (2-wire SMART transmitter with current source)
Voltage dropapprox. 4 V (current source)
Control circuitSL1: 8a(+), 7a(-)
Supply voltagemin. 16 V at 20 mA (2-wire SMART transmitter)
Voltage15 ... 30 V
Signal0/4 ... 20 mA , sink mode , working voltage 15 ... 30 V
Ripple20 mV rms
Analog output
Suitable field devicesI/P converters (positioner), on-site-displays
Signal0/4 ... 20 mA
Field circuitSL2: 5a(+), 5b(-)
Load0 ... 650 Ω
Voltage≥ 13 V at 20 mA
Ripple20 mV rms
Control circuitSL1: 8a(+), 7a(-)
Voltage12 ... 30 V
Signal0/4 ... 20 mA
Line fault detection> 100 kΩ at max. 30 V, with field wiring open
Digital input
Field circuitSL2: 5a(+), 1a(-) (NAMUR sensor)
SL2: 5a(+), 5b(-) (dry contact)
Suitable field devicesNAMUR sensors according to IEC/EN 60947-5-6, dry contacts
Signal0.1 ... 9 mA , sink mode
Open loop voltageapprox. 10 V DC , 1 kΩ series resistance
Signal0.1 ... 9 mA
Control circuitSL1: 8a(+), 7a(-)
Voltage13 ... 30 V
Digital output
Field circuitSL2: 5a(+), 5b(-)
Suitable field devicessolenoid valves, acoustic or visual alarms
Drive capability12 V / 40 mA at 300 Ω load
Internal resistormin. 240 Ω
Current limit45 mA
Open loop voltageapprox. 22 V
Control circuitSL1: 8a(+), 7a(-)
Voltage1-signal: 19 ... 30 V DC
0-signal: 0 ... 5 V DC
Current1-signal: 0 ... 45 mA, depending on the output load
0-signal: < 0.1 mA, independent of the output load
Power dissipation1.1 W at 24 V, 300 Ω load (digital output)
Transfer characteristics
Deviationat 20 °C (68 °F)
≤ ±20 µA incl. linearity, hysteresis and supply fluctuations at 4 ... 20 mA (analog input, analog output)
≤ ±60 µA incl. linearity, hysteresis and supply fluctuations at 0 ... 45 mA (digital output)
Influence of ambient temperature< 2 µA/K (0 ... 60 °C (32 ... 140 °F))
< 3 µA/K (-40 ... 0 °C (-40 ... 32 °F))
Switching frequency≤ 500 Hz with 50 % duty cycle (digital input, NAMUR sensor)
≤ 5 Hz (digital input, dry contact)
≤ 20 Hz (digital output)
Frequency rangeHART: bandwidth by 0.5 Vpp signal and/or 1 mApp signal 950 ... 2500 Hz (analog input, analog output)
Settling time≤ 20 ms (analog input, analog output)
≤ 1 ms (digital input, NAMUR sensor)
Reaction time≤ 5 ms , turn-on/turn-off time (digital output)
Galvanic isolation
Control/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Protection against electrical shockIEC 61010-1:2010
InputEN 60947-5-6:2000
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Mechanical specifications
Degree of protectionIP20
Massapprox. 100 g
Dimensions12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch)
Height128 mm
Width12.5 mm
Length106 mm
Mountingon termination board
Codingpin 1 and 4 trimmed
For further information see system description.
Data for application in connection with hazardous areas
EU-type examination certificateTÜV 14 ATEX 153522 X
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage250 V (Attention! The rated voltage can be lower.)
EquipmentSL2: 5a(+), 5b(-)
Voltage25.2 V
Current110 mA
Power693 mW
Internal capacitance5.7 nF
Internal inductance0 mH
EquipmentSL2: 5a(+), 1b(-)
Voltage< 28 V
Current< 115 mA
Voltage7.2 V
Current0 mA
Power0 mW
Internal capacitance5.7 nF
Internal inductance0 mH
EquipmentSL2: 5a(+), 1a(-)
Voltage12.6 V
Current13 mA
Power41 mW
Internal capacitance5.7 nF
Internal inductance0 mH
CertificateTÜV 14 ATEX 153523 X
MarkingEx-Hexagon II 3G Ex nA II T4 Gc [device in zone 2]
Galvanic isolation
Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
IECEx approvalIECEx TUN 15.0004X
Approved for[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Ex nA II T4 Gc
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210107
ECLASS 12.027210107
ECLASS 11.027210107
ECLASS 10.0.127210107
ECLASS 9.027210107
ECLASS 8.027210107
ECLASS 5.127210107
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: HiC2441

Product Documentation: HiC2441

Language Selection:
Safety and Security DocumentationSprogFil typeFil størrelse
Instruktions manualDANPDF163 KB
Functional Safety ManualENGPDF341 KB
Manuals
System ManualENGPDF5438 KB

Design / Simulation: HiC2441

Language Selection:
CADSprogFil typeFil størrelse
CAD 2-D / CAD 2-DALLZIP16364 KB
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ13 KB
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.