Support Industrielle sensorer
Support Explosion Protection

Power Feed Module S1SD-2PF

S1SD-2PF
  • Interface for Power Bus
  • Supply current 3 A
  • LED status indication
  • Connection via screw terminals

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   S1SD-2PF

Supply
ConnectionPower Bus or terminals 1-, 2+; 7+, 8-
Rated voltage16.8 ... 31.2 V DC
Fusing4 AT with back-up fuse
Power dissipation0.8 W
Output
ConnectionPower Bus
Output currentmax. 3 A
Output voltage24 V DC
Indicators/settings
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Core cross section0.5 ... 2.5 mm2 (20 ... 14 AWG)
Massapprox. 70 g
Dimensions6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1
Height97 mm
Width6.2 mm
Depth107 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
CertificateDEMKO 16 ATEX 1750X
MarkingEx-Hexagon II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010
International approvals
UL approvalE106378
IECEx approval
IECEx certificateIECEx UL 16.0116X
IECEx markingEx nA IIC T4 Gc
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210129
ECLASS 12.027210129
ECLASS 11.027210129
ECLASS 10.0.127210129
ECLASS 9.027210129
ECLASS 8.027210190
ECLASS 5.127210107
ETIM 9.0EC002919
ETIM 8.0EC002919
ETIM 7.0EC002919
ETIM 6.0EC002919
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: S1SD-2PF

Informative Literature: S1SD-2PF

Language Selection:
LiteratureSprogFil typeFil størrelse
Application Report - Sand Trap and Preliminary Sedimentation StageENGPDF448 KB
Product Overview SC-SystemENGPDF456 KB

Product Documentation: S1SD-2PF

Language Selection:
Safety and Security DocumentationSprogFil typeFil størrelse
Instruktions manualDANPDF0 KB
Manuals
System ManualENGPDF2706 KB

Design / Simulation: S1SD-2PF

Language Selection:
CADSprogFil typeFil størrelse
CAD 3-D / CAD 3-DALLSTP4814 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ78 KB
EPLAN macros SC-System devices (EDZ) / EPLAN-Makros SC-System-Geräte (EDZ)ALLZIP4082 KB

Approvals: S1SD-2PF

Language Selection:
CertificatesCertifikat nr.SprogFil typeFil størrelse
Canada UL cULE106378 cUL (QUZW7)ALLLINK---
Europe DEMKO ATEX Category 3 GDEMKO 16 ATEX 1750XALLPDF1876 KB
UL Non-Sparking nA IECEx Certificate of ConformityIECEx UL 16.0116XALLLINK---
USA ULE106378 UL (QUZW)ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0534DALLPDF468 KB

Tilhørende produkter: S1SD-2PF

Matching System Components
1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire transmitters and 2-wire current sources, Current and voltage output, Accuracy 0.1 %, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x 0/2 ... 10 Vpa
1-channel signal conditioner, 24 V DC supply, Input bipolar current and voltage sources, Input 2-wire and 3-wire transmitters, Relay contact output, Restart inhibit, One-shot function, Configurable by DIP switches and software, Connection via screw terminals, Number of channels: 1-channel, Restart inhibit, Time function, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current sourcepa
1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire SMART transmitters and current sources, Output 0/4 mA ... 20 mA, Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, HART communication, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mApa
1-channel signal conditioner, 24 V DC supply, Input current and voltage sources, Current and voltage output, Accuracy 0.1 %, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x 0/2 ... 10 V, Configuration: via DIP switchespa
1-channel signal conditioner, 24 V DC supply, Input bipolar current and voltage sources, Output bipolar current and voltage sources, Accuracy 0.1 %, Configurable via DIP switches and potentiometer, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Signal: 0/2 ... 10 mA, Signal [2]: 0/4 ... 20 mA, Signal [5]: 0/1 ... 5 V, Signal [7]: 0/2 ... 10 V, Line fault detection, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x -10 ... 10 mApa
1-channel signal conditioner, 24 V DC supply, Input bipolar millivolt sources, Output bipolar current and voltage sources, Accuracy 0.1 %, Configurable via DIP switches and potentiometer, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x -10 ... 10 mA, Signal [3]: 1 x -20 ... 20 mA, Signal [4]: 1 x 0/1 ... 5 V, Signal [5]: 1 x 0/2 ... 10 V, Signal [6]: 1 x -5 ... 5 Vpa
1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Dual output 0/4 mA ... 20 mA, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mA, splitter function (1 input and several outputs)pa
1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Input current and voltage sources, Dual output 0/4 mA ... 20 mA, 0/1 V ... 5 V or 0/2 V ... 10 V, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 2 x 0/4 ... 20 mApa
1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors or AC/DC voltage sources, Relay contact output, Timer function, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Time function, Signal type: Digital Input, Rated voltage: 16.8 ... 31.2 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Field device [3]: 2-wire DC sensor, Field device [4]: SN sensor, Field device [5]: S0 sensor, Field device [6]: NPN sensorpa
1-channel signal conditioner, 24 V DC supply, Thermocouple, RTD, potentiometer or mV input, Input for PTC thermistor, Current and voltage output, Line fault (LFD) and sensor burnout detection, Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometer, Field device [2]: Thermocouplepa
1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors, Input frequency 10 mHz ... 50 kHz, Relay contact output, Start-up override and restart inhibit, Configurable by DIP switches and software, Connection via screw terminals, Number of channels: 1-channel, Restart inhibit, Start-up override, Signal type: Digital Input, Rated voltage: 16.8 ... 31.2 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Field device [3]: 2-wire DC sensor, Field device [4]: SN sensorpa
1-channel signal conditioner, Field side loop powered, Current input/output 0/4 mA ... 20 mA, Accuracy 0.1 %, Reverse polarity protection, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 2.2 ... 30 V DC , loop powered, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mApa
2-channel signal conditioner, Field side loop powered, Current input/output 0/4 mA ... 20 mA, Accuracy 0.1 %, Reverse polarity protection, Connection via screw terminals, Number of channels: 2-channel, Signal type: Analog input, Rated voltage: 2.2 ... 30 V DC , loop powered, Signal: 0/4 ... 20 mA, Signal: 2 x 0/4 ... 20 mApa
Matching System Components
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 7.5 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 15 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Cover for DIN mounting rail, Suitable for Power Bus, Standard length 250 mm (9.84 inch), simple to customize to application space, Packaging unit: 5 piecespa
Fixing of the bus carrier with bus PCB in the DIN mounting rail, Termination of DIN mounting rail, Suitable for Power Bus, Packaging unit: 5 pieces left, 5 pieces rightpa