Support Industrielle sensorer
Support Explosion Protection

RFID read/write device IQH3-FP-V1

IQH3-FP-V1
  • Range up to 30 cm
  • Operating frequency 13.56 MHz
  • Conforms to ISO 15693
  • LEDs as function indicators
  • Multi-tag reading of up to 20 tags ensures increased productivity
  • For connection to IDENTControl evaluation unit
  • Degree of protection IP67

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   IQH3-FP-V1

Produkt beskrivelse
HF RFID read/write device, ISO 15693, for IDENTControl
General specifications
Operating frequency13.56 MHz
Transfer rate26 kBit/s
Sensing range
Read distance0 ... 300 mm (see manual)
Write distance0 ... 300 mm (see manual)
Widthmax. 300 mm
MTBF97 a (Operation at +40 °C)
Indicators/operating means
LED greenPower on
LED yellowRead/write operation successful
LED redstatus display
LED blueTransmission mode
Electrical specifications
Current consumption≤ 700 mA
Supplyfrom the IDENTControl
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 300330
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000
Standard conformity
Degree of protectionEN 60529
RFIDISO/IEC 15693-2
ISO/IEC 15693-3
ISO/IEC 18000-3
Approvals and certificates
FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Radio approvalUSA: Contains FCC ID IREIQR3FP
Canada: Contains IC 7037A-IQR3FP
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F) (Operation with nontransmission periods, adjustable)
-25 ... 55 °C (-13 ... 131 °F) (Continuous transmission mode)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPA 6.6
Encapsulation compoundWEVO 403FL/300
Installation
Distance between two headsMultiplex on: ≥ 100 mm
Multiplex off: ≥ 750 mm
Mass385 g
Dimensions
Height40 mm
Width80 mm
Length80 mm

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Details: IQH3-FP-V1

Product Documentation: IQH3-FP-V1

Language Selection:
ManualsSprogFil typeFil størrelse
Manual IQH3-FP-V1ENGPDF1488 KB

Design / Simulation: IQH3-FP-V1

Language Selection:
CADSprogFil typeFil størrelse
CAD 3-D / CAD 3-DALLSTP1062 KB

Approvals: IQH3-FP-V1

Language Selection:
CertificatesCertifikat nr.SprogFil typeFil størrelse
Canada Radio Approval7037A-IQR3FPALLPDF324 KB
India Radio ApprovalETA-SD-20230807834ALLPDF61 KB
USA FCC ApprovalIREIQR3FPALLPDF342 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-7356ALLPDF105 KB
Simplified EU Declaration of Conformity / Vereinfachte EU-Konformitätserklärung   ALLPDF61 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7357ALLPDF103 KB
Australia Declaration of ConformityACMA Supplier's declaration of conformityALLPDF168 KB
FCC Suppliers Declaration of Conformity / FCC-Konformitätserklärung des LieferantenDOC-7358ALLPDF276 KB

Tilhørende produkter: IQH3-FP-V1

Accessories

IDENTControl control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocolsfa

Control interface unit IDENTControl Compactwith serial interface RS-232 and RS-485fa

IDENTControl Compact RFID evaluation unit with interface for PROFIBUS DPfa

IDENTControl Compact control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocolsfa

IDENTControl Compact RFID evaluation unit with EtherCAT interfacefa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa
Control interface unit IDENTControl with PROFIBUS DP interfacefa
Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PUR cable grey, shieldedfa
Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PUR cable black, shielded, UL-approved, drag chain suitablefa
RFID Read/Write Device IUT-F190-B40 with Industrial Ethernet Interface and REST API

Get to know the new IUT-F190-B40, which is designed for medium detection ranges, and can be quickly and easily integrated into OT and IT systems …

Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …